The SL-280 ElectraHawk hand held ionizer delivers a highly refined static eliminating air stream designed for a wide variety of industrial applications. With a balanced static neutralizing 0 +/- 15 Volt output, the SL-280 provides unparalleled blow off capabilities in concert with high efficiency cleaning and MAXIMUM static charge decay.
The gun body and associated cables are lightweight yet highly durable. The gun features a light touch adjustable trigger and an all inclusive operating system for ease of operator convenience. Built in LED lighting serve as indicators of power and ionization. Full functionality is built into the gun including an adjustable air flow control valve.
From delicate components to heavy assemblies the ElectraHawksl-280 has the looks, feel, and performance of a finely crafted tool designed to last a lifetime! Suitable for class 100 Clean Rooms, light weight, durable and easily capable of meeting stringent ESD Standards. Outstanding quality and performance for medical manufacturing and packaging, precision parts assembly, optical particulate removal cleaning of glass and molded parts prior to finishing and static sensitive PC boards and components that are used in the manufacturing of sophisticated static sensitive electronics.
Ion Balance / Off Set Voltage: 0V +/- 15
Blow off force: 180 grams at 100 PSI, 2 inch diameter target, 3" from gun
Gun Construction: Polycarbonate / ABS handle, Polyurethane cable
Input Voltage: 115 VAC Standard / 230 VAC Optional (50 to 60 Hz)
AC Plug Configuration: USA Style Standard / Country Specific Plugs Optional
Size of Power Supply: 200 mm (L) x 135 mm (W) x 89 mm (H)
Handle Weight: 0.8 kg
Total Weight with cables and Power Supply: Approximately 4kg
Maximum Pressure: 100 psi, dry filtered air or nitrogen
Flow / Consumption at 30 PSI: 2.4 SCFM
Flow / Consumption at 60 PSI: 4.6 SCFM
Flow / Consumption at 100 PSI: 7.4 SCFM
Discharge Time: (1000 v to 100 v): 1.3 seconds at 6” and 30 psi, <1.0 sec at 2” and 60 psi
Air Output Pattern: Targeted and easily controllable
Cable Lengths: 2.2 Meter standard, 5.2 Meter length optional
Ozone Generation DIN EM 100-015/1: Compliant - typical output <0.003 ppm @15 cm
Approval: CE, UL and CUL
OSHA: Pressure relief nozzle compliant with OSHA requirements
Noise Levels Measured at 24" from Nozzle: 76 dba at 30 PSI, 89 dba @ 60 PSI, 97 dba @ 100 psi
Final Air Filter Output (replaceable): 1 Micron
Method of Operation: The Power Supply transforms standard electricity into a high voltage charge that is directly coupled to the hardened ionizing electrode pin located in the center of the nozzle. The outer portion of this static dissipative coated nozzle is connected to a reliable earthed ground. The current flow from the pin to the earthed internal portion of the earthed nozzle produces a cloud of positive and negative ions that balances and neutralize a static charge.
When the trigger is depressed a stream of purified compressed air or nitrogen is injected thru this cloud of ions providing a static neutralizing stream that readily removes contaminates and eliminates static induced dust partial re-attachment.
Basic Installation: (detailed instructions are supplied with each unit): The SL-280 is supplied with an 5/16 OD 2 foot long air line and several types of standard quick disconnect connectors with standard hose barbs designed to fit a multitude of US air supply filters. Insure that the compressed air entering the unit is filtered and free of dust, rust, water and other contaminants that may adversely effect the performance of this unit. The power supply unit is equipped with a quick connect push on female fitting. Simply cut the end of the tubing (square cut) and push the air supply tubing into the female fitting while pushing in on the blue collar lock. Insert the tubing into the fitting until the tube bottoms out. Release the locking collar. The tube is now secured to the power supply. Attach the correct hose barb and quick disconnect that is used in your facility to the opposite end of the tubing and attach this fitting to your filtered air supply. Plug the power cord into the power supply. Attach the foot operated power pedal into the back of the power supply
The HV / Air Supply cable is pre-attached to the power supply. Tighten the gland nut if needed. Your unit is now ready to go to work.