Physical Specifications:
Operating Voltage: 110V/60Hz standard, 220V/50Hz optional
Current Consumption: 3.30 to 1.65 Amp
Operating Temperature: 32o F. - 122o F. (0 ~50°c)
Air Coverage: 24" x 24" (60cm x 60cm)
Air Volume: 45~190 CFM
Size (including stand): 22" (L) x 10" (W) x 5" (H)"
Weight: 19 Lbs (8.6kg)
Antistatic aluminum alloy housing.
Positive 1.1
Negative 1.2
Offset Voltage
Postive / Negative < +/- 10 V
Installation Overview: The SL-010 features an attached heavy duty adjustable metal stand with a non marring, non slip base. The SL-010 may be simply placed on work bench, bolted to the underside of a work bench shelve. The SL-010 may also be bolted to work bench overhead beams using the adjustable mounting stand included with your order.
Electrical Requirements: The SL-010 requires 110VAC /60Hz (standard) or 220VAC / 50Hz (optional) power. These units must be grounded. The instrument is equipped with a 3 prong grounded US male plug (standard). Do not modify the plug or use an ungrounded 3 prong receptacle. If an extension cord is required use heavy gauge fully grounded cords only.
Operating Procedure: Activate the SL-010 benchtop ionizing blower by turning fan speed knob clockwise. The ionization indicator will illuminate and indicate the presence of ionized air. Airflow speed can easily be adjusted utilizing the fan speed knob. The time required to neutralize electrostatic potential is dependant on distance of ionizer to work surface and speed of fan. When used in electronic assembly the ionized air stream should cover as much of the working area as possible. The constant flow of ionized air prevents items from developing an electrostatic potential.
Routine Maintenance Overview: Clean emitter as needed. To clean ion emitter point press and turn point cleaner knob (located in middle of air outlet) clockwise approximately one turn and release. Clean air inlet and outlets as needed with a soft brush or vacuum. Periodically test ion output as indicated by your internal esd program or ANSI/ESD S 20.20-2007, TR53, Air Ionizer Compliance Verification (discharge time and offset voltage). Offset voltages of that exceed specification may indicate the need for replacement of emitters. Normal emitter life is 3 years, replacement emitters are easy to install and available from United SCP.
The SL-010 esd bench top ionizer provides a wide, narrowly focused plane of ionized air to control static across a sizable area of an esd benchtop surface. This powerful yet easily controllable ionized air stream is PERFECT for electronic assembly and removing the final traces of static from insulative objects and sub assemblies. One of the most popular style esd benchtop ionizers in the industry!
Compare this product to the high overhead big boys! They make a great unit and so do we. BUT our SL-010 is higher output, competitively priced, ISO manufactured and higher quality! Call United SCP, save your esd program a substantial amount of money and get the high quality and performance you demand from a reliable supplier with a great ionizer and a proven track record!